Solid brass construction for durability and long life.
Refrigerant recovery tank valves.
Refrigerant tank 1 4 flare y valve assembly for 30 or 50 pound cylinders.
For 1 npt tank connection.
Used in conjunction with vapor and liquid recovery valve sets.
The valve is 1 4 flare fittings for mobile or hvac applications and is ported red vapor blue liquid.
The below steps will vary with your recovery machine 5.
Cylinders and the.
3 4 npt port refrigerant tank 1 4 flare tank y valve assembly blue vapor red liquid.
Set the recovery machine to recover.
3 4 npt opening accepts 80 fill with a float switch shut off device.
At the hvac gauges and recovery machine you should see the pressure begin to drop as the refrigerant goes into he recovery tank.
Vapor recovery takes more time than.
Refrigerant tank 1 2 acme y valve assembly for 30 or 50 pound cylinders.
30lb 50lb 100lb 250lb.
Constructed with a y valve for liquid and vapor.
Cylinder working pressure up to 260 psi.
The tank s collar is designed for ease of handling.
Fully open the vapor valve on the recovery.
Start to discharge pressure.
The colors designate the different forms of refrigerant they recover.
Flame king refrigerant recovery cylinder tank reusable dot compliant y valve liquid vapor 30 lb pound 4 7 out of 5 stars 328 amazon s choice for r134a recovery tank.
Ez one shot cylinders use dot 39 disposable cylinder technology to provide an inexpensive lightweight cylinder for use in one time fill recovery situations.
Flame king s 30 pound refrigerant recovery cylinder is powder coated for high gloss and a durable finish.
Relief valve for half ton portable refrigerant tanks.
Be sure to watch the scale as to not overfill the recovery tank a tank should never be filled pass 80 percent.
Purge the hoses of air loosen and unseat the hose connected to the recovery tank until refrigerant is present and then retighten.
The recovery tank valve along with all other valves should be open the recovery machine can be turned on.
Solid brass construction for durability and long life.
Up to 1000 lb.
Standard refrigerant recovery tanks come equipped with both red and blue valves located at the top of the tank.
Refrigerant cylinders include an extra npt opening plugged for future installation of an automatic stop fill liquid level switch stackable 30lb.
Open the high side of the manifold for liquid recovery.
3 4 npt port v20429 manchester refrigerant tank valve assy dual port 600 psi 3 4 mpt fittings.
Red valve knob involves vapor the red valve is a vapor valve used to recover refrigerant in a vapor state.